|
|
| |
|
|
COMPANY PROFILE |
4 th May, 2005 |
|
| |
| A Government Utility
responsible for supply of Electrical Power
and Water includes generation, transmission
and distribution in the city of Dubai and
its suburbs invites applications for the
following positions to be recruited immediately.
They are looking for the following candidates: |
|
01.
SENIOR
CABLE JOINTER & CABLE JOINTER (REF # MNT/51/05)
2 Years Trade certificate in Electrical Technology
or equivalent |
|
5 to 8 years of experience. Shall independently
carryout termination and jointing works
on medium voltage (6.6 / 11 and 33 KV) cables.
Applicant should have good knowledge on
the construction details of XLPE and PILC
power cables and 33 kV pilot cable and should
have thorough hands on experience in different
types Jointing and Termination techniques
employed in heat shrink, cold shrink, pre-mould
type etc. Should have knowledge on Electrical
Safety practices to be employed while working
in medium voltage cables. Should be willing
to work in shifts and round the clock call
duty. |
| |
|
|
02.
ASSISTANT ENGINEER (REF # MNT/52/05)
Bachelor Degree in Electrical Engineering
|
5
years experience in testing of HV switchgear
from 11kV to 400kV, application of state
of the art intelligent units for condition
monitoring of HV & EHV equipment like
GIS, Transformers, OHL & Underground
cables, planning & technical coordination
with consultants/manufacturers. |
| |
|
|
03.
FIRE
ALARM TECHNICIAN (REF # MNT/53/05
2
Years Trade Certificate in Electrical Technology |
| 10
years of experience in FPS system. Experience
in repair & maintenance of fire alarm
control panel, fire alarm devices, fire
water electric pump and Jockey pump controller,
fire water diesel pump controller, Trouble
shooting of fire alarm system and knowledge
in Software programming of analogue addressable
fire detection and alarm system is a must. |
| |
|
|
04.
FOREMAN
(SWITCHGEAR COMMISSIONING) (REF # MNT/54/05)
Diploma in Electrical Engineering/Trade Certificate
(2 yrs.) |
| 5/8 years experience as a testing/supervising person
with a substation contractor or consultant
/ utility in testing and commissioning of
400 / 132 kV GIS, 11 kV & 0.4 kV Switchgears,
snag rectification works during warranty
period and emergency works related to Switchgears
and general substation equipment of 400/132
/11 kV Substations. Must be familiar with
Electrical Scheme drawings and test equipment.
Should have computer knowledge, familiar
with safety practices and proficiency in
English (spoken and written). |
| |
|
|
05.
FOREMAN (TRANSFORMER COMMISSIONING) (REF #
MNT/55/05)
Diploma
in Electrical Engineering/Trade Certificate
(2 yrs.) |
5/8 years experience in testing and commissioning
of large capacity power transformers, shunt
reactors, on load tap changers, trouble
shooting of cooler control circuits and
tap changer circuits of power transformers,
erection of power transformers and shunt
reactors. Experience in operation and maintenance
of oil filtration plant and mechanical works
like oil leak rectification of transformer/shunt
reactors. Knowledge of routine and break
down maintenance of 400/132/33kV power transformers
and 132kV shunt reactors. Training in a
transformer manufacturing industry, utility
or contracting firm in the same discipline.
Should have computer knowledge, familiar
with safety practices and proficiency in
English (spoken and written). |
| |
|
|
06.
SUPERVISOR
(TRANSFORMER) (REF # MNT/56/05)
Diploma in Mechanical Engineering/Trade Certificate
(2 yrs.) |
| 10/15 years experience, in assembly / overhauling
of On Load Tap Changers of Power Transformers.
The incumbent shall be responsible for supervising
/ carrying out periodic inspection and overhauling
of On Load Tap Changers and also for training
his subordinate staff. The candidate should
have hands on experience in assembly / overhauling
of On Load Tap Changers of prominent makes
like MR, ABB etc. and shall be capable of
taking corrective actions independently.
Also, he must have flair for repairing /
re-assembling of mechanical equipment /
machines. (Preference will be given to those
who have working experience in a Tap Changer
manufacturing industry). Possession of UAE
driving license and knowledge of computer
applications preferred. |
| |
|
|
07.
JUNIOR
ENGINEER (SWITCHGEAR COMMISSIONING) (REF #
MNT/57/05)
Bachelor Degree/Diploma
in Electrical Engineering |
| 5/10 Years experience in EHV substation testing
and commissioning with an utility/ consultant/turnkey
contractor. Shall be familiar with Testing
and Commissioning of switchgears in EHV
substations. Shall be capable of working
as witnessing engineer for EHV substation
SWGR testing. Shall be able to supervise
erection, testing & commissioning activities
of EHV substation equipment such as GIS,
Transformer, MV/LV switchgears, etc. Literacy
in computer. |
| |
|
|
08.
ASSISTANT ENGINEER (CABLE TESTING & FAULT
LOCATION) (REF # MNT/58/05)
.Degree
or Diploma in Electrical & Electronics
Engineering |
7/12
years experience in a reputed utility/Industry
in attending 33kV, 11kV and 6.6kV Power/Pilot
cable Fault location and repair, maintenance
of 33/11-6.6kv and 11/6.6-0.4kv substation
equipment as per relevant quality standards
Should have excellent coordinating capabilities
with external and internal agencies. Should
have in depth knowledge of Electrical Safe
Working Procedures for Medium voltage systems
in accordance with International standards,
very good supervisory skills. Should be
willing to work in shifts and round the
clock call duty. Experience in the VLF &
diagnostic testing of medium voltage Cables. |
| |
|
|
09.
ELECTRICIANS (TRANSMISSION) (REF # MNT/59/05)
2
yrs. Trade Certificate in Electrical Technology |
|
5 years experience in erection, commissioning
and maintenance of substation equipments
of 132kV or 400kV substation. He shall be
conversant with control circuit of High
Voltage Gas Insulated Switchgear, Low Voltage
AC Supply, Air Compressors, Diesel Generator
sets, Transformers, Substation lighting
etc. Knowledge of safety, computer knowledge
etc will be an added advantage. |
| |
|
|
10.
ELECTRICIANS
(CABLE TESTING) (REF # MNT/60/05)
2 yrs. Trade Certificate in Electrical Technology |
| 5 years experience in a reputed utility /construction
or process Industry in the relevant field.
Thorough knowledge in the maintenance of
substation equipments like transformers,
circuit breakers, control panels, wiring
of electrical installations, LV cable laying
and termination, trouble shooting of electrical
equipments, experience in Medium voltage
cable etc. Should be able to understand
electrical circuit drawings and carry out
jobs with minimum supervision. Should be
willing to work in shifts and round the
clock call duty. |
| |
|
|
11.
FOREMAN
(FIRE PROTECTION SYSTEM) (REF # MNT/61/05)
Diploma in Mechanical Engineering |
| 10
years of experience in Fire protection system.
Experience in repair & maintenance of
deluge valves, fire pumps and diesel engine,
compressor & pressure tanks, instrumentation
e.g. pressure switch, flow switch, flow
meter etc. Knowledge of safety, computer
knowledge etc will be an added advantage. |
| |
|
|
12.
MECHANIC
(FIRE PROTECTION SYSTEM) (REF # MNT/62/05)
2
yrs. Trade Certificate in Mechanical Technology |
| 10 years of experience in repair maintenance and
troubleshooting of firewater pump engine
& fire pumps. |
|
|
| Contd
Page 2.. |
|
|